L'adhésif de la surface d'essai sur microtension affecte la résistance de l'Union entre une céramique feldspathique et le ciment en résine?

Authors

  • Luiz Felipe Valandro Universidade Federal de Santa Maria
  • Mutlu Özcan University Medical Center Groningen, University of Groningen
  • Regina Amaral Universidade Estadual Paulista
  • Sheila Pestana Passos Universidade Estadual Paulista
  • Marco Antonio Bottino Universidade Estadual Paulista

DOI:

https://doi.org/10.17267/2596-3368dentistry.v1i1.3

Keywords:

Tensile bond strength, Ceramic, Cement

Abstract

Purpose: To evaluate the effect of the bonded surface area on the bond strength of a resin cement to a glass ceramic. Methods: Surfaces of 12 glass ceramic blocks (6x6x4mm3) were conditioned with 10% hydrofluoric acid and silanizated. The conditioned blocks were placed inside a silicone mold and the dual-cure resin cement was applied on the treated surface. Specimens were stored sectioned for obtaining samples with different bonded surface areas: Gr1 - 0.7mm x 0.7mm (0.5mm²), Gr2 - 1mm x 1mm (1mm²), Gr3 - 1.4mm x 1.4mm (2mm²). The non-trimmed beam samples were submitted to the microtensile bond strength test in a universal testing machine (cross-head speed: 1 mm/min). Data were statistically analyzed (ANOVA and Tukey’s test;? Pearson Correlation test). Results: The microtensile bond strength results were significantly affected by the bonded surface area (p<.0001). The highest bond strength (MPa) was of the Gr1 (26.3±8.2a), followed by Gr2 (20.8±6.5b) and Gr3 (16.1±5.7c). The Pearson correlation test revealed that there is an inverse correlation between bonded surface area and microtensile bond strength results (r=-0.5234; p<0.0001). Conclusion: The lowest bonded surface areas provided the highest values of bond strength.

Downloads

Download data is not yet available.

Author Biographies

  • Luiz Felipe Valandro, Universidade Federal de Santa Maria
    DDS, MSc, PhD, Professor Adjunto, Universidade Federal
    de Santa Maria, Departamento de Odontologia
    Restauradora, Santa Maria-RS, Brasil
  • Mutlu Özcan, University Medical Center Groningen, University of Groningen
    DMD, PhD, Professora e Pesquisadora Associada,
    University Medical Center Groningen, University of
    Groningen, Department of Dentistry and Dental Hygiene,
    Groningen, The Netherlands
  • Regina Amaral, Universidade Estadual Paulista
    DDS, Mestranda em Prótese, Universidade Estadual
    Paulista, Faculdade de Odontologia de São Jose dos
    Campos, São José dos Campos-SP, Brasil
  • Sheila Pestana Passos, Universidade Estadual Paulista
    DDS, MSc, doutoranda em Prótese, Universidade
    Estadual Paulista, Faculdade de Odontologia de São Jose
    dos Campos, São José dos Campos-SP, Brasil
  • Marco Antonio Bottino, Universidade Estadual Paulista
    DDS, PhD, Professor Adjunto, Universidade Estadual
    Paulista, Departamento de Materiais Dentários e Prótese,
    São José dos Campos-SP, Brasil

Published

2018-06-29

Issue

Section

Original Articles

How to Cite

L’adhésif de la surface d’essai sur microtension affecte la résistance de l’Union entre une céramique feldspathique et le ciment en résine?. (2018). Journal of Dentistry & Public Health (inactive Archive Only), 1(1). https://doi.org/10.17267/2596-3368dentistry.v1i1.3

Most read articles by the same author(s)

<< < 1 2 3 4 5 6 7 8 9 10 > >>